Power efficiency comparisons for 64-port gateways usually quote a figure taken from a label or a product page. Neither describes a device that spends its life transmitting on every port, and the difference is large enough to change the operating cost.
This article sets out why idle figures mislead, how to measure draw under sustained load, how to convert that into an operating cost, why cooling is the second cost, and the protocol that makes two models comparable.
Why do idle figures mislead when comparing power efficiency of 64-port gateways?
Because transmission is the load.
A gateway draws a fraction of its operating current when it is idle, and several times that when every port is transmitting, so a figure taken at rest describes a device that is not working.
The mechanism is straightforward and its consequences are not. Radio transmission dominates the power profile, so the draw follows the traffic rather than the clock. A rack that has been measured on a bench will therefore appear more efficient than the same rack in service, and the discrepancy grows with port count, because more ports means more simultaneous transmitters and a larger gap between the idle and peak figures.
The same reasoning applies to comparisons between models. Two devices with similar idle figures can differ substantially under load, and a comparison conducted at idle will rank them in an order that has no relationship to their operating cost. The radio characteristics under transmission, including the conditions under which terminal equipment is specified, are described in 3GPP TS 45.005, and the harmonised terminal standard for the European market is published as ETSI EN 301 511.
| Measurement | What it describes | When it is useful |
|---|---|---|
| Idle draw | The floor | Standby planning only |
| Peak draw | The design load | Supply and circuit sizing |
| Sustained draw over a busy hour | The operating cost | Comparing models |
| Draw per delivered message | The efficiency that matters commercially | Cost per message calculation |

How do you measure draw under sustained load?
Measure at the rack feed, during a real campaign.
The measurement needs three readings: at idle, at the sustained load the deployment actually runs, and at the peak it occasionally reaches.
The instrument matters less than the placement. Reading at the wall gives a figure that includes the supply conversion losses and the auxiliary equipment, while reading at the device excludes them; both are legitimate and only one should be used for a given comparison. Whichever is chosen, record it, because a comparison between a wall measurement and a device measurement is not a comparison.
The duration matters as much as the value. A momentary peak and a sustained load at eighty per cent of it have different consequences for anything with a thermal or storage element, and the sustained figure is the one that predicts operating cost. Record the load profile alongside the reading: how many ports were active, what the message rate was, and for how long. Without that context the figure cannot be compared with anything, including a later reading from the same device.
Converting draw into operating cost
Multiply by hours and by the local rate.
The calculation is arithmetic once the sustained figure is known, and its value is that it puts a hardware decision into the same units as the rest of the operating budget.
Three inputs are required: sustained draw in watts, assumed hours of operation, and the cost of energy at the site. The result is an annual figure per device, which can then be divided by the port count to give a cost per port and by the delivered volume to give a cost per message. That last figure is the one that belongs in a comparison between models, because it accounts for both the power drawn and the work delivered.
Two refinements keep the arithmetic honest. First, use the sustained figure rather than the peak, since the peak is occasional and including it overstates the annual cost. Second, include the auxiliary draw of anything installed with the unit, such as a fan tray or a small switch, because those are part of the installation and are often measured separately. Where the site has a generator or an uninterruptible supply, the figure also determines what has to be sized behind it, which is the next section.

Cooling load as the second cost
Every watt consumed becomes a watt of cooling.
The thermal load is the same figure as the electrical load, so the cost of a device includes removing the heat it produces as well as supplying it with power.
Where the room is cooled as a whole, the cooling cost is proportional to the total heat load and is not attributable per device unless someone measures the population and the cooling energy together. Where the rack is cooled locally, the relationship is more direct: the cooling unit draws power proportional to the heat it removes, and the efficiency of that conversion is worth confirming rather than assuming.
The consequence for a comparison is that a model drawing slightly more power can cost materially more once cooling is included, and the difference compounds in a dense rack. The environmental expectations for telecommunications equipment are addressed in ITU-T K.20 and ITU-T K.21, with the test regime in ITU-T K.44, and they describe the conditions equipment may be expected to tolerate rather than how a room should be arranged.
How do you compare two models fairly?
Same load, same duration, same measurement point.
A comparison is only meaningful when the two devices deliver the same work under the same conditions at the same point in the power path.
The work has to be defined, which is why the draw per delivered message is the most useful figure: two units can be compared on the energy each consumes to deliver the same volume under the same conditions. Where one device delivers more because its radios are configured differently, the comparison shifts from efficiency to capability, and the honest conclusion is that they are not comparable in the way the exercise assumed.
The measurement point is the second requirement. A comparison that measures one device at the wall and another at the device includes different conversion losses, and at 64 ports those losses are not negligible. Choose one point, state it, and apply it to both. Environmental and physical protection controls, including the requirements around power and environmental conditions, are organised in NIST SP 800-53 Rev. 5.

Where efficiency matters most
In dense installations and in sites with constrained power.
Efficiency is worth optimising where the rack population is high, where the power budget is fixed, or where the site depends on a battery or a generator.
Each of those changes the arithmetic. In a dense rack, the difference per device compounds across dozens of units. In a site with a fixed power budget, efficiency decides how many units can be installed rather than how much they cost to run. In a site with backup power, the same figure determines how long the battery lasts and how much generator capacity has to be provided, which is often the largest single consequence and the one most often overlooked during procurement.
The reverse is equally true. In a small installation in a temperate room with abundant power, the difference between two efficient designs is a rounding error against the cost of the site visit required to measure it. Efficiency belongs in the comparison where it changes a decision, not as a general criterion.
A measurement protocol
The protocol fixes the load, the measurement point and the period before any reading is taken, because power figures are only comparable when all three are stated. It is written to be run once per model and repeated when the configuration or the load profile changes.
- Define the load: how many ports active, at what message rate, for how long.
- Choose a measurement point and use it for every device in the comparison.
- Record idle draw, sustained draw over a busy hour, and peak draw.
- Record the load profile alongside the readings so they can be compared later.
- Compute cost per port and cost per delivered message from the sustained figure.
- Add the auxiliary draw of anything installed with the unit.
- Include cooling, or record that it was excluded.
- Repeat the measurement after any change to the rack population.
The protocol produces a figure that can be used twice: once to choose between models and once to plan the site. A deployment that has measured its gateway population can size its power and cooling from evidence, which is the practical reason to run the exercise at all.
Two habits keep the figure usable. Record the measurement point and the load profile with the result, because a power figure without either is not comparable with anything. And re-measure after any change to the rack population, since adding units changes both the total load and the airflow that the same cooling has to serve. Most power and thermal surprises in this class of installation come from growth that was never reflected in the original measurement.
Where the site has a fixed power allocation, the measurement also answers a capacity question: how many units of this model can be installed before the supply or the cooling becomes the constraint. That figure is worth having before an expansion is planned, because it moves the discussion from a purchase decision to a site decision.
Measure the sustained figure, not the label. Send your port count, load profile and site power constraints to service@telarvo.com, or review the published configurations on the SK-SMS Gateway range and the TGW gateway page. Telarvo publishes the SK-SMS gateway range, the TYH modem pools and the TGW SMS machine on its product pages, and the configurations referenced above come from those listings.
FAQ
How much power does a 64-port gateway use?
There is no single figure that applies across models, and the published list pages for this range do not state a power draw. Measure a sample at idle and under sustained load at the rack feed, and use the sustained figure for planning. A label figure or an idle measurement will understate the operating load. Take the sustained reading while every port is transmitting, because that is the condition the supply has to support.
Should power be measured at the wall or at the device?
Either, provided the same point is used for every device in the comparison. Wall measurements include conversion losses and auxiliary equipment, device measurements exclude them. Comparing one device at the wall against another at the device produces a result that reflects the measurement point rather than the hardware. State the point in the record, because a later reader will otherwise assume the wall figure.
Does cooling really need to be included?
It changes the ranking in dense installations, so it should at least be recorded as included or excluded. Every watt consumed becomes heat that has to be removed, so a model drawing more power costs more twice. Where the room is cooled as a whole, attribute the cooling proportionally or state that it was omitted. A stated omission is usable; an unstated one corrupts the comparison.
Which figure should be used to compare two models?
Energy per delivered message under the same conditions. Cost per port is useful for site planning, and it does not capture differences in how much work each device delivers. Compare on the work done for the energy consumed, and state the measurement point and the load profile with the result. The comparison is only meaningful when both figures come from the same test.
{
“@context”: “https://schema.org”,
“@type”: “FAQPage”,
“mainEntity”: [
{
“@type”: “Question”,
“name”: “How much power does a 64-port gateway use?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “There is no single figure that applies across models, and the published list pages for this range do not state a power draw. Measure a sample at idle and under sustained load at the rack feed, and use the sustained figure for planning. A label figure or an idle measurement will understate the operating load. Take the sustained reading while every port is transmitting, because that is the condition the supply has to support.”
}
},
{
“@type”: “Question”,
“name”: “Should power be measured at the wall or at the device?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Either, provided the same point is used for every device in the comparison. Wall measurements include conversion losses and auxiliary equipment, device measurements exclude them. Comparing one device at the wall against another at the device produces a result that reflects the measurement point rather than the hardware. State the point in the record, because a later reader will otherwise assume the wall figure.”
}
},
{
“@type”: “Question”,
“name”: “Does cooling really need to be included?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “It changes the ranking in dense installations, so it should at least be recorded as included or excluded. Every watt consumed becomes heat that has to be removed, so a model drawing more power costs more twice. Where the room is cooled as a whole, attribute the cooling proportionally or state that it was omitted. A stated omission is usable; an unstated one corrupts the comparison.”
}
},
{
“@type”: “Question”,
“name”: “Which figure should be used to compare two models?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Energy per delivered message under the same conditions. Cost per port is useful for site planning, and it does not capture differences in how much work each device delivers. Compare on the work done for the energy consumed, and state the measurement point and the load profile with the result. The comparison is only meaningful when both figures come from the same test.”
}
}
]
}